Intensity (candlepower) table for five planes Separate tabulations provided for beam side and opposite-to-beam side, if different.
Intensity (candlepower) polar graph for 0, 45 and 90 degree planes For axially symmetric luminaires, mean intensity (candlepower) tables and graphs are provided.
Output lumens
Zonal lumens and percentages
Efficiency
Paint reflectance (if applicable)
Spacing criteria, spacing to mounting height ratio
Luminance table and summary For axially symmetric luminaires, mean luminance tables and summaries are provided.
Coefficients of utilization
IES file
“LSI Tested” service mark
Luminaire description and diagram
Operating watts at nominal volts (fluorescent, incandescent and LEDs)
Lamp watts, nominal (HID)
Note: Test reports are available also in CIE format. Please request details.
Indoor Luminaire Testing
Incandescent
Each additional lamp in luminaire
Straight fluorescent with downlight only or uplight only:
Up to four straight lamps
More than four straight lamps
HID and Compact Fluorescent:
One lamp in luminaire
Each additional lamp in luminaire
Luminaires with both downlight and uplight:
Add to above prices
LED/SSL luminaires (Absolute Testing):
Additional Measurements/Reports:
Visual Comfort Probability (VCP), with or without uplight, for any illuminance level
Cone of light tabulation
Wall and ceiling exitance coefficients
Lighting design tables– number of luminaires for various illuminance levels in room sizes 20 x 20 ft. to 100 x 100 ft.
Isolux diagram (zero room reflectances)
Wall wash vertical illumination table
Minimum bulb wall temperature
Ballast case temperature
Ballast installation charge
Ballast factor measurements
Additional test on same luminaire not requiring remounting or recalibration (10% less)
Non-quadrilaterally symmetric
Outdoor Luminaires (excluding Floodlights)
Standard Test Report Includes:
Cutoff classification
IESNA Classification (Type I-IV, short, medium, long) and associated graph showing maximum and 50% maximum isocandela.
Intensity (candlepower) summary table, with vertical and horizontal angles of maximum intensity identified
Graph and table of intensity (candlepower) in the plane of maximum intensity (non-axially symmetric luminaires only)
Graph and table of mean intensity (candlepower) in the vertical plane (axially symmetric luminaires only)
Graph and table of intensity (candlepower) in the cone of the maximum intensity (non-axially symmetric luminaires only)
Percentage output: Front (street) side and rear (house) side, downlight and uplight
Efficiency: Downlight, uplight and total
Utilization Factor (Coefficient of Utilization) graph and table for front (street) and rear (house) sides
Iso-illuminance graph with mounting height conversion table (footcandles or lux)
Illuminance table for a single luminaire
Note: Test reports are available also in CIE format. Please request details.
Outdoor Luminaire (excluding Floodlights) Testing
Luminaires with downlight only or uplight only, single lamp:
Axially symmetric distributions (Type V)
Other distributions (measurements in 58 lateral planes)
Luminaires with both downlight and uplight:
Add to above prices
Additional measurements/Reports:
Each additional lamp in luminaire
Isocandela diagram (rectilinear or “Onion” diagram)
Tilted luminaire report, available without re-photometering luminaire
Complete report including isolux
Isolux and utilization only
Floodlights
Standard Test Report Includes:
IES/NEMA classification
Maximum intensity (candlepower), vertical and horizontal location of maximum
Field angle, field lumens and efficiency
Beam angle, beam lumens and efficiency
Total lumens and efficiency
Spill light lumens
Intensity table and graph through origin
Isocandela diagram
Table of zone center intensities and zonal lumens
IES file
“LSI Tested” service mark
Luminaire description and diagram
Operating watts at nominal volts (fluorescent, incandescent and LEDs)
Lamp watts, nominal (HID)
Floodlight Testing
Axially symmetric distributions
Other distributions, including totally asymmetric
Additional measurements/Reports:
Iso-illuminance diagram
Spotlights and Tracklights
Note: All testing is performed assuming axial symmetry; for non-symmetrical distributions, see Floodlights above
Standard Test Report Includes:
Maximum intensity (candlepower)
Beam center intensity (candlepower)
Field angle, field lumens and efficiency
Beam angle, beam lumens and efficiency
Total lumens and efficiency
Efficiency: Excepting for absolute tests
Efficacy: For absolute tests
Graph of intensity (candlepower) through origin
Tabulation of intensity (candlepower) through origin vs. angle and cosine
Cone of light tabulation – distance vs. beam center illuminance, beam diameter and beam edge illuminance
Tabulation of distance versus illuminance, beam diameter and field diameter
Lighting design tables – distance versus beam center illuminance, illuminated (beam) width, illuminated (beam) length, and spacing for aiming angles of 0, 30, 45 and 60 degrees
IES file
“LSI Tested” service mark
Luminaire description and diagram
Operating watts at nominal volts (fluorescent, incandescent and LEDs)
Lamp watts, nominal (HID)
Spotlight and Tracklight Testing
Lamp types other than double-ended HID
Double-ended HID
Upon request
Flashlights and Portable Lighting
Testing is performed in accordance with ANSI/NEMA standard FL1-2009. More extensive photometric testing is also available for the full beam distribution.
ANSI/NEMA FL1 2009 Testing:
Three samples are required to be tested for compliance. The below pricing includes three samples:
Photometric testing and report of Maximum Beam Distance and Peak Beam Intensity
Run time on batteries
Light output (total lumens)
Water resistant
Waterproof
SubmersibleUpon request
Bare Lamps
Goniophotometer test and report includes:
Intensity (candlepower) distribution table and graphs
Zonal lumens
Electrical: Volts, Amps, Watts
Efficacy
IES file
Note: All bare lamp photometry is performed using a commercial ballast. For reference ballast, add $125 per lamp. For spectral testing, see next section.
Sphere Testing – Lumen Output, Electrical and Spectral Data
Applicable to luminaires or bare lamps.For Solid State Lighting (LEDs), see next section.
Option 1.Lumen Output and Electrical Data:
Absolute lumen output
Electrical: Volts, Amps, Watts
Efficacy
Option 2.Spectral Data:
Spectral Power Distribution table and graph
Correlated Color Temperature (CCT)
Color Rendering Index (CRI)
Chromaticity Coordinates (x, y, u’, v’)
CIE Chromaticity Diagram
Option 3.Combined Lumen Output, Electrical Data and Spectral Testing
Combination of Options 1 and 2 above, performed at same time
Note: Additional samples of the same product when tested at the same time may be offered at reduced cost; please request quotation.
Solid State Lighting Products
LED Lamps and Luminaires:
Testing services for Energy Star for SSL and the Quality Advocates Lighting Facts label include all required LM-79 (LM79) services.